Titan Electrical Solutions
EICR testing across South Wales

Landlord and homeowner EICRs, done properly

Every circuit tested, every observation coded and photographed, and a fixed written price for any remedial work before anything is booked. NICEIC Domestic Installer, available 8am to 9pm, seven days a week.

Get a fixed EICR price

🔒 No spam. Fast response, 8am – 9pm 7 days a week.

What the codes mean

C1 Danger present

Something on the installation presents an immediate risk of injury, for example exposed live parts. We make it safe on the day where we can and it is reported straight away. A C1 means the report is unsatisfactory.

C2 Potentially dangerous

Not dangerous right now, but it could become so, for example missing earthing or bonding. A C2 also makes the report unsatisfactory and needs remedial work before a satisfactory report can be issued.

C3 Improvement recommended

The installation is safe but does not meet the current standard, for example no RCD protection on a circuit that would need one today. A C3 on its own does not fail the report.

FI Further investigation required

Something could not be fully assessed during the inspection and needs more work to establish whether it is a fault. An FI also results in an unsatisfactory report until it is resolved.

Read the full guide to C1, C2, C3 and FI codes

How the inspection runs

  1. 1
    Booking and access
    We agree a slot, including evenings and weekends, and confirm who is providing access to the consumer unit, intake position and every room.
  2. 2
    Visual inspection
    Accessories, protective devices, bonding and cable condition are inspected before any instrument is used.
  3. 3
    Dead testing
    Power is off in stages while continuity, insulation resistance and polarity are tested circuit by circuit.
  4. 4
    Live testing
    Earth fault loop impedance and RCD operation are measured with the supply restored.
  5. 5
    Coding and report
    Every observation is coded C1, C2, C3 or FI, photographed, and written up in plain English alongside the schedule of test results.
  6. 6
    Remedials, if needed
    Anything that needs putting right is quoted in writing at a fixed price. You are free to use another electrician, and we will still verify and re-issue.

Common questions

What is an EICR?

An Electrical Installation Condition Report is a formal inspection and test of the fixed wiring in a property. It records the condition of the installation against BS 7671 and codes anything that falls short.

How often does a rented property need one?

Domestic rented property in England and Wales is generally on a five-year cycle, with a copy provided to tenants. Check the current guidance from your local authority for your specific situation.

How long does an EICR take?

Most domestic properties take two to four hours depending on the number of circuits. HMOs and subdivided houses take longer because each supply is inspected separately.

Does the power have to go off?

Yes, in stages. Dead testing requires the circuits to be isolated, so plan for the supply to be interrupted for parts of the visit.

What makes a report unsatisfactory?

Any C1, C2 or FI observation. C3 observations are recommendations and do not on their own make a report unsatisfactory.

Who carries out the inspection?

Work is carried out by Titan Electrical Solutions, a fully qualified NICEIC Domestic Installer, to BS 7671 18th Edition Amendment 2.