If you have had a quote elsewhere, we are happy to look at it and explain the differences. If the readings do not support the work, you will be told that before anything is booked.

This page is for anyone in Swansea trying to work out whether no power in one room is their next job or next year's. The trick is testing before replacing, not the other way round. Where the answer is to leave it alone for now, that is exactly what we will tell you. Two properties on the same street can differ on this entirely.

Swansea sits in West Glamorgan and we reach most SA1–SA7 addresses within the same working day. The practical question for a Swansea property is not what usually happens, but what this installation actually shows when it is tested. Neither of us benefits from finding that out halfway through. The purpose of this page is to make no power in one room in Swansea predictable rather than mysterious.

Safe checks you can do first

  • Check the consumer unit — is any breaker in the 'off' position?
  • Try a different appliance in the dead socket in case the appliance is the fault.
  • Check whether lights in the same room work — sockets and lighting are usually on separate circuits.

Likely causes

  • A tripped MCB on the ring final circuit that hasn't been noticed — the label is often wrong or missing.
  • A loose neutral or line at a socket terminal — usually the last socket that was worked on.
  • A failed switched fused spur feeding a spur run for that room.
  • A cable damaged by a picture nail, screw or radiator bracket at the same height as buried cabling.

When to stop and call

If the breaker is up, sockets are fully dead, and there's no visible damage, call — the fault is inside the wiring.

How we fix it

We continuity-test the ring, identify the break point, and repair or replace the affected accessory. If a cable is damaged behind plaster, we agree the cheapest access route with you before opening anything up.

Typical price: £85–£150 for diagnosis and a single accessory replacement. Cable repairs behind plaster are quoted after inspection.

Swansea context

That's the difference between a £85 fix and a £2,000 board that you didn't need. The regulations set the standard; no power in one room sets the effort required to meet it at your particular address in Swansea Council. The paperwork explains it in the same words we would use on site.

FAQs — no power in one room in Swansea

Do I need a rewire if one room has no power?+

Almost never. It's usually one loose terminal or one damaged accessory — 90% of these calls are fixed on the first visit.

Will you need to lift floorboards?+

Only if the fault is under the floor. We locate the fault first, then agree access with you before opening anything.